94,590    130    3  

Makita DC18RA: Ombygging fra 110V til 220V

 43     0
Hei alle sammen!

Etter jeg skrev min vellykket ombygging av Makita'en DC18RA har jeg fått etterspørsel om å legge ut en liten beskrivelse, så nå har jeg endelig fått snekret sammen en beskrivelse med bilder og beskrivelser.

Den er på dessverre på engelsk men tror ikke det blir noe problem.

Takker mxlars ettersom beskrivelsen er basert på hans artikkel her på forumet.
Signatur

  (trådstarter)
   #1
 43     0

How to mod your Makita DC18RA from 110v to 220v.


Disclaimer:
I don't take any responsibility if the content of this page might lead to your charger blowing up, it shouldn't, buy hey you never know. Anyways this is just a description of how I did it, and it worked for me.
How to mod your Makita DC18RA from 110v to 220v. - 24072008151.jpg - magua
Signatur
  (trådstarter)
   #2
 43     1

The charger.


I bought the Makita set 18V LXT601 from Maxtool which included the named charger. The problem is that due to some safety regulations in the US the chargers comes without a swicht for 220v. So some moding is required to make the charger work for 220v.

So no! Under no circunstancies plug the unmodified charger  on a 220v current outlet, otherwise you will blow up the condensator/capasitator inside, and it will problaby take with it some other components.

So for the charger to work on 220v you have to remove two components, which are a condensator and a varistor.

Signatur
  (trådstarter)
   #3
 43     0

Opening the box.


The first step is to remove the screws on the back, easy enough.
Opening the box. - 24072008134.jpg - magua
Signatur
  (trådstarter)
   #4
 43     0

The components.


So as said, the two components you need to change are a varistor and a condensator, as they are place on the board as you see in the picture, it should be easy enough. The varistor could be tricky but in this case is easy as it is the one with the plastic capsule on it.

A varistor is also known as Voltage Dependent Resistor or VDR and are often used to protect circuits against excessive transient voltages by incorporating them into the circuit in such a way that, when triggered, they will shunt the current created by the high voltage away from the sensitive components.

So the varistor (and not varisator, that's a typo) that has to be changed is the 140-150 volts which is way to low for us. What we need is to change it for one that can take 250 volts.

The condensator is the big one you see in the picture, this also has to be removed for one that can take more than 350v, the value about 180-400uF, but you don't have to be so exact about it apparently.
The components. - components.jpg - magua
Signatur
  (trådstarter)
   #5
 43     0


I got my condensator and varistor from an old power supply, as you can see in the picture, I removed the old condensator, the new condensator takes 450v and value of 140uF but it worked ok for me.
The components. - 24072008144.jpg - magua
Signatur
  (trådstarter)
   #6
 43     0

Soldering the new components into place.


The varistor and the condensator are soldered into place, just be carefully with the polarity of the condensator. Use wikipedia if you are unsure about the polarities.

Soldering the new components into place. - soldered.jpg - magua
Signatur
  (trådstarter)
   #7
 43     0


So  while you are it, why not also remove the old 110v contact and use the European standard contact for 220v.
Soldering the new components into place. - 24072008150.jpg - magua
Signatur

   #9
 21,481     Enebolig     0
Jeg liker ikke tukle med slike ting med mindre det er HELT sikkert at det er sånn det skal være  Smile

Ellers ville jeg prøvd tror jeg.
   #10
 177     1
Hei!
Det er merkelig at ikke laderene er bygget for å fungere mellom 100V til 240V slik som ladere til laptop`er, mobiltelefoner etc eller omstiller bryter som på strømforsyning til pc-er. Skulle være helt unødvendigt at den må bygges om for å fungere her.
Signatur